Level
Instruments
|
Gauges
|
Flow
meters
FLOW METER
MAGENTIC
INDUCTIVE FLOW METER:
Electromagnetic
flow meters measure the volumetric flow rate of electrically
conductive liquids & Slurries.
Highlights:
- The Specialist for water and waste water measurement.
- Hard Rubber, Neoprene or Polyurethane liner.
- For flow rates up to 300,000 m/h and more.
- Meter sizes DN 25-3000 and 1"-120", fitting length
also in conformity with ISO.
----------------------------------------------------------------------------------------------------------------------------------------------
Flowmeter to measure the volumetric flow rate of electrically
conductive liquids. It has Smooth inner tube and no pressure
loss.
Highlights:
- Reliable expert for all industrial applications and measurement
for process liquids.
- Wafer design.
- Easy, quick and low cost of installation.
- PTFE Liner.
- Rugged and proven design.
- Absolutely maintenance free.
----------------------------------------------------------------------------------------------------------------------------------------------
Primary Head for Water and Waste Water Measurements
Highlights:
- Reliable expert for water and wastewater measurement.
- Wafer design.
- Easy, quick and low cost of installation.
- Hard rubber liner.
- Rugged and proven design.
- Absolutely maintenance free.
----------------------------------------------------------------------------------------------------------------------------------------------
Electromagnetic Flowmeter
A reliable "expert" for industrial
applications and flow measurements of process liquids and
slurries.
----------------------------------------------------------------------------------------------------------------------------------------------
Food version:
SMS CONNECTION is available for uses
in the Food and Beverage Industry:
Available for separate or compact systems with PTFE / PFA
liner, with stainless steel electrodes and housing made of
mild steel or stainless steel.
----------------------------------------------------------------------------------------------------------------------------------------------
Hazardous version:
The primary heads are approved for use in Hazardous
Area Class I, IIA and IIB:
Remote signal converters are available in field housing for
use in hazardous areas.
Highlights:
- The Specialist for process liquids and slurries.
- PTFE or PFA Liner.
- For flowrates upto 300, 000m /h and more.
- Meter sizes DN 10-3000 and 3/8"-120", fitting
length also in conformity with ISO.
----------------------------------------------------------------------------------------------------------------------------------------------
VARIABLE
AREA FLOW METER :
Variable-area Flowmeter: The standard
solution for the process industry measure the volumetric
or mass flow rate of liquids, gases and vapors.
Highlights:
- Consistent overall length.
- Low pressure loss for gas applications.
- Measurement at operating pressures up to 3000 bar.
- Measurement at extremely low and high process temperatures
( -200...+450°C ).
- Fast non-interruptive retrofitting of modules.
- The only EHEDG-certified variable-area flowmeter approved
for use in food & pharmaceutical applications.
- Without dead spaces, CIP/SIP-compatible.
- SIL 2 certified.
- Complete family with different displays.
- Local indication without the need for auxiliary power.
- Measurement in all flow directions.
- Rugged design for extreme operating conditions.
- Flexible and can be adapted to meet customer-specific requirements.
----------------------------------------------------------------------------------------------------------------------------------------------
The solution for all metal flow meters
DK- all metal flow meters are suitable for measuring the volumetric
or mass flow rate of liquids, gases and vapors. Thanks to
the rugged design, the flow meters are especially suitable
for difficult operating and environmental conditions.
----------------------------------------------------------------------------------------------------------------------------------------------
Variable-area Flowmeter
these flow meters are suitable for measuring the
volume flow rate of liquids and gases.
Highlights:
- Simple installation and start-up.
- Compact design.
- Low maintenance.
- Limit monitors are optional.
- All variants come with high quality needle valves.
- No wearing parts.
- Fragment protection.
- Robustly built for many uses.
- Local display without auxiliary power.
- Excellent long-term stability.
- Adaptable to meet customers' requirements.
----------------------------------------------------------------------------------------------------------------------------------------------
VORTEX
FLOW METER
This is the only vortex flowmeter
with integrated pressure (optional) and temperature compensation
in 2-wire technology. This flow meter provides accurate measurement
of operating, standard volumetric and mass flow of conductive
and non-conductive liquids, gases and vapors even with fluctuating
pressures and temperatures.
Highlights:
- 2-wire device with integrated pressure (optional) and temperature
compensation.
- Wear resistant, fully welded stainless steel vortex shedding
structure with high corrosion, pressure and temperature resistance.
- Optimum process reliability thanks to Flodoc Intelligent
Signal Processing - stable readings, free of external disturbances.
- Maintenance-free sensor design.
----------------------------------------------------------------------------------------------------------------------------------------------
The all-in-one solution
This is the only vortex flowmeter with integrated pressure &
temperature compensation in 2-wire technology. This model provides reliable measurement of operating,
standard, volumetric and mass flow of conductive & non
- conductive liquids, gases and vapours, even with fluctuating
pressures and temperatures.
Highlights:
- 2-wire device with integrated pressure and temperature compensation.
- Non -wearing, fully welded stainless steel construction
with high corrosion, pressure and temperature resistance.
- Optimal process reliability thanks to Intelligent Signal
Processing (ISP) - stable readings, free of external perturbations.
- Ready to use immediately thanks to plug & play.
- Maintenance free sensor design.
- PACTware available at no extra cost.
- Pressure & Temperature can be called up via HART.
----------------------------------------------------------------------------------------------------------------------------------------------
ULTRASONIC FLOW METER
Standard solution in the process industry
This model is a 3-beam ultrasonic flowmeter for liquids. It measures independent of conductivity, viscosity, temperature,
density and pressure.
Highlights:
- Three beams generate a measurement effectively independent
of flow profile.
- Major performance improvement by applying innovative electronics
and digital signal processing (DSP).
- Optional pressure and temperature inputs for calculation
of standardised volumetric flow or mass flow according to
API 2540 or customer specifics.
- Over 20.000 ultrasonic flow meters installed worldwide.
- Easy to install and operate.
- No moving or intruding parts, no wear, no drift, therefore
no additional pressure loss.
- No material build-up as unobstructed flow sensor with smooth
surface finish.
- No periodic re-calibration or maintenance.
- Insensitive to corrosive or abrasive products.
- Excellent long-term stability and reliability.
----------------------------------------------------------------------------------------------------------------------------------------------
-ALTOSONIC
V
5 - Beam ultrasonic flowmeter for custody transfer of liquid
hydrocarbons.
This has established itself as the standard
in multibeam custody transfer flow metering. The absence of
obstructions or moving parts in the pipe, ensures no wear
or pressure loss. This, in combination with larger meter sizes
permits simplified configuration of metering systems. For
example no strainers and less parallel lines are required.
Operation is maintenance free. No periodic calibration is
required, drastically cutting cost for on-site equipment and
procedures. This all results in considerable cost savings
in both capital (CAPEX) and operation expenditure (OPEX).
New line extensions make multi beam flow metering a more cost
effective and viable alternative for low viscosity applications.
There is also a line extension for extremely difficult heavy
crudes.
Highlights:
- High reliabilty.
- Compliant with OIML R117 and API.
- No K-factor shift: no periodic re-calibration required.
- No incidents of unscheduled interruption of operation since
the introduction in 1996.
- Rugged and reliable construction.
- Large dynamic range.
- Bi-diectional flow measurement.
- Integrated diagnostics.
---------------------------------------------------------------------------------------------------------------------------------------------
Dual beam ultrasonic flowmeter for high-temperature refined
products.
This model is a dual beam ultrasonic flow meter for crudes
and a broad range of refined products that are processed under
extreme conditions (high temperature / high pressure).
This with its robust industrial construction performs
with minimum operational – and maintenance costs, due to a
solid fully welded construction without any moving parts and
hence no wears.
Highlights:
- Major performance using digital signal processing (DSP).
- Excellent long term stability and reliability.
- No moving or intruding parts.
- Maintenance free and without need for periodic recalibration.
- Robust construction, resistant to corrosive and abrasive
products.
- Dual parallel paths for Reynolds independency.
top
|